FarrWest

ISCO 6712 Composite Sampler

Daily Rate $60

Weekly Rate $175

Monthly Rate $500

The 6712 Portable Sampler features a vacuum-formed ABS plastic shell to withstand exposure and abuse. Its tapered design and trim 20-inch (50.8 cm) diameter result in easy manhole installation and removal. Large, comfortable handles make transporting safe and convenient – even when wearing gloves. The NEMA 4X, 6 (IP67) enclosure is submersible, watertight, and dust-tight. Plug-in 700 Series Modules and the SDI-12 interface make it easy to add flow and parameter monitoring to your 6712-based system.

Description


ISCO 6712 Composite Sampler

Full Size Composite Sampler

6712 Full-Size Portable SamplerThe 6712 Portable Sampler features a vacuum-formed ABS plastic shell to withstand exposure and abuse. Its tapered design and trim 20-inch (50.8 cm) diameter result in easy manhole installation and removal. Large, comfortable handles make transporting safe and convenient - even when wearing gloves. The NEMA 4X, 6 (IP67) enclosure is submersible, watertight, and dust-tight. Plug-in 700 Series Modules and the SDI-12 interface make it easy to add flow and parameter monitoring to your 6712-based system.


ISCO's advanced 6712 Controller allows you to select different programming modes to assure the most suitable routine for your application. Programming is fast and simple, with on-line help just a key stroke away.
In Standard Programming Mode, the controller walks you through the sampling sequence step-by-step, allowing you to choose all parameters specific to your application. Extended Programming Mode lets you enter more complex programs including “smart sampling” event notification, triggered on any combination of up to 16 inputs.


Feature

Features

  • SDI-12 interface provides “plug and play” connection with multi-parameter water-quality sondes and other compatible devices.

  • Standard 512kB memory gives you great flexibility for logging environmental data.

  • Choice of 11 different glass and plastic bottle configurations ranging from 24 x 1liter to 1 x 5.5 gallon.

  • NEMA 4X, 6 (IP67) controller enclosure

  • Rugged ABS plastic shell

Applications

  • Wastewater effluent

  • Stormwater Monitoring

  • CSO Monitoring

  • Permit Compliance

  • Pretreatment Compliance

Specifications

General

Size (H x Dia):
27 x 20 in (68.6 x 50.7 cm)
Weight
Dry, less battery–32 lbs (15 kg)
Bottle Configurations
24 – 1 Liter PP or 350 ml Glass
24 – 1 Liter ProPak Disposable Sample Bags
12 – 1 Liter PE or 950 ml Glass
8 – 2 Liter PE or 1.8 Liter Glass
4 – 3,8 Liter PE or Glass
1 – 9,5 Liter PE or Glass
1 – 5.5 gallon (21 Liter)PE or 5 gallon (19 Liter
Glass, (with optional Jumbo Base)
Power Requirements
12 VDC

Pump

Suction Tubing
Length
3 to 99 ft (1 to 30 m)
Material
Vinyl or Teflon
Inside Dimension
3/8 in (1.0 cm)
Pump Tubing Life
Typically 1,000,000 pump counts
Maximum Lift
28 ft (8.5 m)
Typical Repeatability
± 5 ml or ± 5 of the average volume in a set
Typical Line velocity at head height of
@ 3 ft (0.9 m) head height: 3.0 ft/s (0.91m/s)
@10 ft (3.1 m) head height: 2.9 ft/s (0.87 m/s)
@15 ft (4.6 m) head height: 2.7 ft/s (0.83 m/s)
Liquid Presence Detector
Non-wetted, nonconductive sensor detects
when liquid sample reaches the pump to
automatically compensate for changes in
head heights.


Controller

Dimensions (HxWxD):
10.3 x 12.5 x 10.0 in (26.1 x 31.7 x 25.4 cm
Weight (dry):
13 lbs (5.9 kg)
Operating Temperature:
32 to 120 °F (0 to 49 °C)
Enclosure Rating:
NEMA 4X, 6 (IP67)
Program Memory:
Non-volatile ROM
Flow Meter Signal Input:
5 to 15 volt DC pulse or 25 millisecond
isolated contact closure
Number of Composite Samples:
Programmable from 1 to 999 samples
Real Time Clock Accuracy:
1 minute per month, typical

Software

Sample Frequency
1 minute to 99 hours 59 minutes, in 1 minute
increments. Non-uniform times in minutes or
clock times 1 to 9,999 flow pulses
Sampling Modes
Uniform time, non-uniform time, flow, event.
(Flow mode is controlled by external flow
meter pulses.)
Programmable Sample Volumes
10 to 9,999 ml, in 1 ml increments
Sample Retries
If no sample is detected, up to 3 attempts;
user selectable
Rinse Cycles
Automatic rinsing of suction line up to 3
rinses for each sample collection
Program Storage
5 sampling programs
Sampling Stop/Resume
Up to 24 real time/date sample stop/resume
commands
Controller Diagnostics
Tests for RAM, ROM, pump, display, and
distributor

Resources