Solinist

LeveLogger Edge

The Levelogger Edge is an absolute (non-vented) water level datalogger, which measures groundwater and surface water levels and temperature. Water levels are displayed as temperature compensated pressure readings, and can be barometrically compensated with the aid of a Barologger.

Add to Quote

Specifications

Level Sensor Piezoresistive Silicon with Hastelloy Sensor
Ranges 15, 10, 20, 30, 100, 200 m
Accuracy ± 0.05% FS
Normalization Automatic Temp Compensation
Temp. Comp. Range 0ºC to 50ºC
Temperature Sensor Platinum Resistance Temperature Detector (RTD)
Temp. Sensor Accuracy ± 0.05ºC
Temp. Sensor Resolution 0.003ºC
Battery Life 10 years (based on 1 reading/minute)
Clock Accuracy (typical) ±1 minute/year (-20ºC to 80ºC)
Operating Temperature -20ºC to 80ºC
Maximum # Readings 40,000 sets of readings
Memory Continuous or Slate mode
Communication Speed 9600 bps, 38,400 bps with USB optical reader
Com Interface Optical Infra-red: USB, RS-232, SDI-12
Size 22 mm x 159 mm (7/8" x 6.25")
Weight 129 grams (4.5 oz.)
Corrosion Resistance Titanium based PVD coated body and superior corrosion resistant Hastelloy sensor
Other Wetted Materials Delrin, Viton, 316L Stainless Steel
Sampling Modes Linear, Event & User-Selectable Schedule with Repeat Mode, Future Start, Future Stop, Real Time View
Measurement Rates 0.125 second to 99 hours
Barometric Compensation High accuracy, air-only, Barologger Edge